HEPA and ULPA filters both remove airborne particles, but they are designed for different levels of contamination control. HEPA filters are suitable for most cleanroom and HVAC applications, while ULPA filters are used for environments that require higher filtration efficiency.

DTAFIL provides customized HEPA and ULPA filter solutions for cleanrooms, industrial facilities, and specialized filtration systems. This guide compares their efficiency, grades, applications, and selection factors to help you choose the right filter.

What Are HEPA and ULPA Filters?

HEPA & Filtres ULPA

HEPA filters balance performance and cost for most cleanrooms, while ULPA filters provide extreme filtration for sensitive processes at a higher operational cost.

HEPA (High-Efficiency Particulate Air) Filters

HEPA filters are the standard choice for high-efficiency air filtration. They are designed to capture at least 99.97% of particles at 0.3 µm, providing reliable contamination control for most cleanroom and HVAC applications.

Commonly used in ISO Class 5–8 cleanrooms, HEPA filters offer a practical balance between filtration efficiency, airflow resistance, and operating cost. They are widely applied in pharmaceutical manufacturing, healthcare facilities, laboratories, and general industrial environments.

COLÈRE (Ultra-Low Penetration Air) Filters

ULPA filters provide a higher level of particle removal for applications requiring extreme cleanliness. They can capture at least 99.999% of particles around 0.12 µm, making them suitable for environments where even trace contamination can affect product quality.

These filters are mainly used in ISO Class 3–4 cleanrooms, including semiconductor manufacturing, advanced electronics, and other ultra-critical processes.

HEPA vs ULPA: What Are the Main Differences?

HEPA & Filtres ULPA

The choice between HEPA and ULPA filters is a direct trade-off: ULPA offers higher efficiency for smaller particles but at a significant cost to airflow, energy, and budget.

Comparison Factor HEPA Filters Filtres ULPA
Particle Removal Efficiency ≥99.97% at 0.3 µm ≥99.999% at around 0.12 µm
Typical Cleanroom Class ISO Class 5–8 ISO Class 3–4
Airflow Resistance Lower pressure drop and easier airflow Higher pressure drop due to denser media
Energy Consumption Lower operating energy requirements Higher energy consumption due to airflow resistance
Initial Cost More economical and widely available Higher purchase cost
Typical Applications Healthcare, pharmaceuticals, laboratories, Systèmes CVC Semiconductor manufacturing, microelectronics, ultra-critical cleanrooms

How Do HEPA and ULPA Filters Work?

These filters are not simple sieves. They use a chaotic maze of fibers to physically capture particles of all sizes through a combination of impaction, interception, and diffusion.

The Three Core Particle Capture Mechanisms

HEPA and ULPA filters do not work like simple sieves. They capture airborne particles through three main mechanisms:

  • Inertial Impaction: Larger particles cannot follow airflow changes and collide with filter fibers, where they are trapped.
  • Interception: Medium-sized particles follow airflow paths and are captured when they contact fiber surfaces.
  • Diffusion: Ultrafine particles move randomly due to Brownian motion, increasing the chance of contact with fibers.

Understanding the Most Penetrating Particle Size (MPPS)

Filter efficiency reaches its lowest point at the Most Penetrating Particle Size (MPPS), typically around 0.1–0.3 µm for HEPA filters. This is why filters are tested at their MPPS to verify worst-case performance.

Particles larger than the MPPS are mainly captured through impaction and interception, while smaller particles are captured through diffusion. ULPA filters achieve higher efficiency by optimizing the filter media structure to improve the capture of ultrafine particles.

Source Certified HEPA & ULPA Filters for Your Application

Need the right filtration solution for your cleanroom or HVAC system? Our engineering team provides OEM HEPA and ULPA filters with customized dimensions, certified performance testing, and reliable factory-direct support.

Get a Custom Filter Quote →

HEPA and ULPA filter solutions

How Are HEPA and ULPA Efficiency Grades Classified?

HEPA and ULPA filter grades are classified by the EN 1822 standard, which evaluates performance based on worst-case efficiency at the Most Penetrating Particle Size (MPPS).

When a filter is labeled as H14 or U15, the classification represents a verified efficiency level defined by EN 1822, rather than a general marketing description. This standard specifies the classification, testing methods, and performance requirements for EPA, HEPA, and ULPA filters.

Filter Class Type de filtre Efficiency at MPPS Typical Applications
H13 HEPA ≥99.95% General cleanrooms, laboratories, healthcare facilities
H14 HEPA ≥99.995% Pharmaceutical production, critical cleanrooms, biosafety laboratories
U15 COLÈRE ≥99.9995% Semiconductor manufacturing, advanced electronics
U16 COLÈRE ≥99.99995% Ultra-clean manufacturing processes
U17 COLÈRE ≥99.999995% Most demanding contamination control applications

Which Filter Designs, Médias, Frames, and Seals Are Available?

250 350 HEPA filter5

A filter’s performance depends on its physical construction. The design, media, frame, and seal must all match the specific demands of the application and environment.

Filter Designs and Geometries

The physical shape of a filter dictates how it fits into equipment and handles airflow. You’ll encounter a few standard configurations in the field.

  • Box (panel) and cylindrical cells are the workhorses for terminal units, laminar flow hoods, and specialized equipment where air is pushed through a contained space.
  • Pleated media packs increase the filter’s surface area, which is crucial for balancing efficiency and airflow.
  • V-bank or compact filters arrange multiple media packs into a V-shape within a single frame. This design handles high airflow volumes in large HVAC systems while minimizing the pressure drop, making it a common choice for facility-wide cleanroom air handling.

Filter Media Types and Materials

The filter media is the engine of the system, and its material determines the filter’s efficiency, durability, and pressure drop.

  • Glass fiber (microglass) is the traditional high-efficiency medium. It provides excellent filtration but is fragile and can be damaged by improper handling, which compromises its integrity.
  • Synthetic polymer and PTFE membrane media are more robust alternatives. They offer greater durability, a lower pressure drop for the same efficiency, and better resistance to moisture or chemicals, making them suitable for tougher environments.

Frame Constructions and Materials

The frame provides the structural support and interface for installation. The material and design are selected based on the operational environment.

  • Frames are typically made from acier galvanisé, acier inoxydable, or lightweight aluminum. The choice depends on factors like weight limits, corrosion risk, and cost.
  • Stainless steel frames are standard in pharmaceutical or biocontainment areas. These environments demand high corrosion resistance to withstand frequent, aggressive cleaning and disinfection cycles.
  • Frame designs also include functional features like protective face guards to prevent media damage, internal support structures, and specific flanges for mounting securely into filter housings.

Seal and Gasket Configurations

Proper sealing is essential because air bypass around the filter media can reduce the effective filtration performance of the system.

  • Knife-edge and gel seal systems create an extremely reliable, leak-free seal. In this setup, a blade on the filter frame sinks into a channel of gel in the housing.
  • Compression gaskets made from neoprene, EPDM, or silicone are a more common and cost-effective solution for general HEPA installations where the leak-tightness requirements are less extreme.
  • The decision between a gel seal and a gasket comes down to the required leak integrity of the system, the installation type, and whether mandatory in-situ leak testing (like PAO scanning) is part of the operational protocol.

Where Are HEPA and ULPA Filters Used?

HEPA filters are workhorses in healthcare, industry, and homes. ULPA filters are reserved for ultra-critical applications like advanced semiconductor manufacturing where near-perfect particle removal is mandatory.

The applications for high-efficiency filters are vast, but the choice between HEPA and ULPA is driven entirely by the level of contamination control required. One is a versatile standard, the other is a specialized tool.

Industry HEPA Applications ULPA Applications
Pharmaceutique GMP cleanrooms, aseptic production areas, laboratories High-critical sterile environments requiring extreme contamination control
Healthcare Operating rooms, isolation rooms, ICUs, medical laboratories Limited use in highly controlled medical and research environments
Semi-conducteur General clean manufacturing areas and equipment filtration Wafer fabrication, ultra-clean processes, advanced semiconductor production
Électronique Component assembly areas and general contamination control Advanced microelectronics and precision manufacturing
Industriel Dust collection, hazardous particle filtration, industrial air purification Rarely used except for ultra-sensitive industrial processes

HEPA filters are widely used in healthcare, pharmaceutical manufacturing, electronics, laboratories, and other environments where airborne particle control is required. For applications involving elevated operating temperatures, high temperature HEPA filters are designed with specialized materials and construction to maintain filtration performance under demanding conditions.

How to Select and Specify the Right Filter

Proper filter selection isn’t just about efficiency. It requires matching filter grade and pressure drop to your cleanroom class, HVAC limits, and total lifecycle costs.

Selection Stage Key Specification Actions

Assess Cleanliness Requirements and Process Risk

  • Map the required cleanroom standard (par ex., ISO Class 5–8) to the necessary filter grade (HEPA for most applications, ULPA for ISO 3–4).
  • Identify the critical particle size that poses a risk to the product or process (par ex., ≥0.3 µm vs. ≥0.12 µm).
  • Select H13/H14 HEPA for general life sciences and healthcare, reserving U15+ ULPA for microelectronics or ultra-critical aseptic zones.
  • Ensure the chosen filter class complies with governing industry standards like ISO 14644, EN 1822, and GMP guidelines.

Evaluate HVAC System Compatibility and Constraints

  • Compare the filter’s pressure drop against your fan’s static pressure capacity, as ULPA filters create significantly higher resistance.
  • Verify the filter’s physical dimensions and sealing type (gel, gasket) match your existing housings or fan filter units.
  • Acknowledge that upgrading to ULPA may require fan upgrades, additional filter area, or system redesign to handle the higher pressure.
  • Define acceptable initial and end-of-life pressure drop limits to ensure compatibility with the air handling system.

Define Critical Parameters in the Specification

  • State the exact efficiency class (par ex., H14, U15) and the governing test standard (par ex., EN 1822).
  • Specify the rated airflow (CFM or m³/h) at which the filter’s performance is certified.
  • Lock in construction details, including frame material, media type, and sealing method (gel or gasket).
  • Mandate that each filter ship with an individual factory test report and define protocols for on-site acceptance testing.

Plan for Lifecycle Cost and Ongoing Validation

  • Calculate the total cost of ownership, factoring in filter price, energy use from pressure drop, and replacement labor.
  • Establish a monitoring plan using differential pressure gauges to track filter loading over time.
  • Set a clear replacement trigger, typically when the final pressure drop reaches double its initial value.
  • Schedule periodic in-situ leak testing (par ex., annually) to validate filter integrity and maintain compliance.

Testing, Maintenance, and Custom Procurement

A filter’s lifecycle is a closed loop. Test standards dictate procurement, and factory data sets the baseline for maintenance, ensuring long-term system reliability and controlled costs.

Filter Testing and Certification

Ensuring a HEPA or ULPA filter performs as rated isn’t a matter of trust; it’s a matter of testing. Filters undergo verification both at the factory and after installation (in-situ) to confirm their efficiency and integrity. These procedures follow established industry standards to ensure consistency and reliability.

  • Governing Standards: Key protocols include EN 1822, OIN 29463, and the IEST Recommended Practices (RPs), which outline methods for classification and testing.
  • Core Tests: The two most critical tests are leak scanning and efficiency measurement. Leak scanning detects physical defects like pinholes or seal failures, while overall efficiency is measured at the filter’s Most Penetrating Particle Size (MPPS) to verify its capture rate under worst-case conditions.
  • Individual Certification: Each filter destined for a critical application must ship with its own test certificate. This document provides traceable proof of its actual performance, including its measured efficiency, pressure drop at a rated airflow, and the results of its leak scan.

Routine Maintenance and Replacement

A filter’s performance degrades over its service life. A structured maintenance program is essential for tracking this decline and replacing filters before they compromise system integrity or efficiency. This involves routine monitoring and periodic re-verification.

Maintenance programs focus on monitoring the differential pressure (ΔP) across the filter, which indicates how loaded orcloggedit is. Visual inspections for physical damage to the media, frame, or seals are also performed. To confirm the ongoing integrity of installed filters, periodic in-situ testing is conducted, often annually or semi-annually, depending on the criticality of the environment.

A filter is typically replaced when one of the following conditions is met:

  • It fails an in-situ leak test.
  • Its pressure drop exceeds the pre-defined final limit, which compromises system airflow.
  • It sustains obvious mechanical or chemical damage.

Custom Procurement Specifications

Procuring high-efficiency filters requires a detailed technical specification, not just a simple purchase order. Your PO must clearly define the performance and construction requirements to ensure you get what you pay for. Key specifications include the filter class (par ex., H14, U15), required airflow capacity, precise dimensions for the housing, and materials compatible with the operating environment.

A critical, non-negotiable line item in any purchase order is the mandate for individual factory testing and certification. This ensures every single filter meets performance criteria before it even ships. For specialized applications, procurement specifications can include more advanced parameters, such as low-outgassing media and sealants for microelectronics, chemical-resistant components for pharmaceutical cleanrooms, or high-temperature construction for industrial processes.

Foire aux questions

What is the difference between HEPA and ULPA filters?

The primary difference is filtration efficiency for very small particles. HEPA filters capture at least 99.97% de 0.3 µm particles. ULPA filters are more efficient, capturing at least 99.999% of even smaller particles around 0.12 µm. This higher performance comes at the cost of increased pressure drop, higher price, and a shorter service life.

What efficiency grades are classified as HEPA and ULPA?

Under the EN 1822/ISO 29463 normes, filters are classified into different grades. HEPA filters correspond to classes H13 (≥99.95% efficiency) and H14 (≥99.995%). ULPA filters are even more efficient, falling into classes U15 (≥99.9995%), U16, and U17. Lower efficiency filters (E10-E12) are considered EPA filters, not HEPA.

Is ULPA always better than HEPA for a cleanroom?

No, ULPA is not automatically the better choice. While it offers higher filtration efficiency, it creates more airflow resistance, which increases energy consumption and requires more powerful fans. HEPA filters provide sufficient performance for many cleanroom applications, such as ISO Class 5 and above, and are often preferred due to lower operational costs and longer lifespan. ULPA is typically justified only for the most critical environments, such as advanced semiconductor manufacturing.

Which industries typically require H13, H14, or ULPA filters?

H13 and H14 HEPA filters are standard in healthcare (operating rooms), pharmaceutical manufacturing (GMP cleanrooms), and life science labs. H14 is used for more critical applications like aseptic filling lines. ULPA filters are required in industries with extreme contamination control needs, primarily semiconductor fabrication (Classe ISO 1-4), advanced microelectronics, and high-risk aseptic zones.

Final Thoughts

HEPA and ULPA filters are not interchangeable. HEPA filters meet the needs of most cleanroom and HVAC applications, while ULPA filters are designed for ultra-critical environments where strict particle control is required.

The right choice depends on your cleanliness requirements, airflow system, and operating conditions. Contact our engineering team for OEM filter specifications and customized filtration solutions.

Get in Touch

Popular Blogs

Il semble que nous ne trouvons pas ce que vous cherchez.

Obtenez votre solution de filtration personnalisée dès aujourd'hui

Connectez-vous avec notre équipe d’ingénierie pour une consultation technique gratuite. En tant qu'usine directe, nous offrons un accompagnement de bout en bout, depuis la sélection des matières premières jusqu'à la livraison du produit final.
Prix ​​direct usine-1
Prix ​​​​directs en usine
100Salle blanche de classe K-1
100Salle blanche de classe K
OEM personnalisé & R.&J-1
OEM personnalisé & R.&D
Livraison mondiale rapide-1
Livraison mondiale rapide

Contactez-nous

image popup
Partir si tôt? Optimisons vos coûts de filtration.

Besoin de solutions personnalisées? Déposez vos exigences ci-dessous et nos ingénieurs vous fourniront un devis direct en usine dans les délais 12 heures.

Téléchargez le dernier catalogue électronique principal DTAF

Obtenez un accès complet aux spécifications techniques, courbes de performances aérodynamiques, et capacités OEM/ODM d'une Fortune 500 fabricant de filtration de confiance.

Prix ​​direct usine-1
Prix ​​​​directs en usine
100Salle blanche de classe K-1
100Salle blanche de classe K
OEM personnalisé & R.&J-1
OEM personnalisé & R.&D
Livraison mondiale rapide-1
Livraison mondiale rapide

Demande de téléchargement

*Nous respectons votre confidentialité et toutes les informations sont protégées.