Maison

>

Équipement de purification

>

Salle blanche & Système de laboratoire

>

Cold-rolled steel painted single-person air shower with single blower

Cold-rolled steel painted single-person air shower with single blower

The single-person air shower is an essential purification device for personnel entering cleanrooms or dust-free workshops. Highly versatile, it can be used in conjunction with all types of cleanrooms and clean facilities. Staff must pass through this unit upon entering the workshop, where powerful, clean air is blown from rotating nozzles in multiple directions onto the body, effectively and quickly removing dust, hair, dander, and other contaminants clinging to clothing. This helps significantly reduce pollution caused by personnel entering and exiting cleanrooms.
Highlights
1. Photoelectric sensing, automatic misting.
2. Double-door electrically controlled interlock made of stainless steel.
3. Stainless steel nozzle.
4. Utilizing an advanced silent system, the operation is quieter and has less impact on the workers who are currently working.

Product Features

Maintenance Points

  1. Periodic Testing: Regularly measure the equipment’s technical specifications using instruments. If the parameters do not meet requirements, address them promptly.

  2. Filter Cleaning: Depending on actual usage, periodically remove the filter media from the primary air filter for cleaning.

  3. Check Air Velocity: If a decrease in air velocity is observed, first inspect the surface of the primary air filter. If it appears dark/black, it indicates excessive dust accumulation and increased resistance. In this case, remove the non-woven fabric within the primary filter to clean or replace it.

  4. Replace HEPA Filter: If replacing or cleaning the non-woven fabric does not restore the air velocity, the HEPA filter is likely clogged, resulting in increased resistance. In this case, replace the HEPA filter.

  5. HEPA Filter Installation: To replace the HEPA filter, remove the nozzle plate, extract the old filter, and replace it with a new one matching the original specifications. When installing, ensure the arrow on the HEPA filter points in the direction of the airflow. Ensure the seal is secure to prevent leakage.

  6. Leakage Test: After replacing the HEPA filter, confirm there is no leakage around the frame. Conduct a test using a particle counter; the unit may only resume normal operation once it meets the required technical standards.

  7. Electrical Maintenance: Regularly inspect electrical circuits. If faults occur, refer to the electrical schematic diagram for repairs.

  8. Door Maintenance: Regularly maintain the door to ensure the electronic lock aligns with the lock hole, preventing the locking pin from jamming.

  9. Temperature Restrictions: The operating temperature of this equipment must not exceed 50°C. Open flames are strictly prohibited.

Model / Specifications Single Person, Single Blow Single Person, Double Blow Two Persons, Double Blow Three Persons, Double Blow Four Persons, Double Blow Tunnel Type
Applicable Number of People 1 1 2 3 4
Air Shower Time 0-99S (Adjustable)
Number of Nozzles 6 12 12 16 24 60
Nozzle Diameter φ38mm
Nozzle Air Velocity 15-20MS
Filter Efficiency 99.99%
Air Shower Area Dimensions (W×D×H) 800×860×1890 800×860×1890 800×1060×1890 800×1360×1890 800×1860×1890 800×4860×1890
External Dimensions (mm) 1300×1000×2050 1600×1000×2050 1600×1200×2050 1600×1500×2050 1600×2000×2050 1600×5000×2050
Power Supply 3P 380V 50Hz / 1P 220V 50/60 Hz (Optional)
Max Power (W) 700 1400 1400 1400 2800 5600
Weight Approx. 250 Approx. 300 Approx. 350 Approx. 500 Approx. 600
HEPA Filter Dimensions / Qty 610×610×120
(1 unit)
610×610×120
(2 unités)
800×610×120
(2 unités)
915×610×120
(2 unités)
610×610×120
(4 unités)
610×610×120
()

Entrer en contact

*Nous respectons votre confidentialité et toutes les informations sont protégées.
WhatsApp

Obtenez votre solution de filtration personnalisée dès aujourd'hui

Connectez-vous avec notre équipe d’ingénierie pour une consultation technique gratuite. En tant qu'usine directe, nous offrons un accompagnement de bout en bout, depuis la sélection des matières premières jusqu'à la livraison du produit final.
Prix ​​direct usine-1
Prix ​​​​directs en usine
100Salle blanche de classe K-1
100Salle blanche de classe K
OEM personnalisé & R.&J-1
OEM personnalisé & R.&D
Livraison mondiale rapide-1
Livraison mondiale rapide

Contactez-nous

Contactez-nous

image popup
Partir si tôt? Optimisons vos coûts de filtration.

Besoin de solutions personnalisées? Déposez vos exigences ci-dessous et nos ingénieurs vous fourniront un devis direct en usine dans les délais 12 heures.

Téléchargez le dernier catalogue électronique principal DTAF

Obtenez un accès complet aux spécifications techniques, courbes de performances aérodynamiques, et capacités OEM/ODM d'une Fortune 500 fabricant de filtration de confiance.

Prix ​​direct usine-1
Prix ​​​​directs en usine
100Salle blanche de classe K-1
100Salle blanche de classe K
OEM personnalisé & R.&J-1
OEM personnalisé & R.&D
Livraison mondiale rapide-1
Livraison mondiale rapide

Demande de téléchargement

*Nous respectons votre confidentialité et toutes les informations sont protégées.