Heim

>

Blog

>

HEPA- und ULPA-Filter: Ein vollständiger Leitfaden zur Effizienz, Noten, und Anwendungen

HEPA- und ULPA-Filter: Ein vollständiger Leitfaden zur Effizienz, Noten, und Anwendungen

Inhaltsverzeichnis

HEPA and ULPA filters both remove airborne particles, but they are designed for different levels of contamination control. HEPA filters are suitable for most cleanroom and HVAC applications, while ULPA filters are used for environments that require higher filtration efficiency.

DTA-DATEI bietet customized HEPA and ULPA filter solutions for cleanrooms, industrial facilities, and specialized filtration systems. This guide compares their efficiency, grades, applications, and selection factors to help you choose the right filter.

What Are HEPA and ULPA Filters?

Aluminum-partition-HEPA-filter

HEPA filters balance performance and cost for most cleanrooms, while ULPA filters provide extreme filtration for sensitive processes at a higher operational cost.

HEPA (High-Efficiency Particulate Air) Filters

HEPA filters are the standard choice for high-efficiency air filtration. They are designed to capture at least 99.97% of particles at 0.3 µm, providing reliable contamination control for most cleanroom and HVAC applications.

Commonly used in ISO Class 5–8 cleanrooms, HEPA filters offer a practical balance between filtration efficiency, airflow resistance, and operating cost. They are widely applied in pharmaceutical manufacturing, healthcare facilities, laboratories, and general industrial environments.

ZORN (Ultra-Low Penetration Air) Filters

ULPA filters provide a higher level of particle removal for applications requiring extreme cleanliness. They can capture at least 99.999% of particles around 0.12 µm, making them suitable for environments where even trace contamination can affect product quality.

These filters are mainly used in ISO Class 3–4 cleanrooms, including semiconductor manufacturing, advanced electronics, and other ultra-critical processes.

HEPA vs ULPA: What Are the Main Differences?

Dichter plissierter Hepa-Filter

The choice between HEPA and ULPA filters is a direct trade-off: ULPA offers higher efficiency for smaller particles but at a significant cost to airflow, energy, and budget.

Comparison Factor HEPA Filters ULPA-Filter
Particle Removal Efficiency ≥99.97% at 0.3 µm ≥99.999% at around 0.12 µm
Typical Cleanroom Class ISO Class 5–8 ISO Class 3–4
Airflow Resistance Lower pressure drop and easier airflow Higher pressure drop due to denser media
Energy Consumption Lower operating energy requirements Higher energy consumption due to airflow resistance
Initial Cost More economical and widely available Higher purchase cost
Typical Applications Healthcare, pharmaceuticals, laboratories, HVAC-Systeme Semiconductor manufacturing, microelectronics, ultra-critical cleanrooms

How Do HEPA and ULPA Filters Work?

These filters are not simple sieves. They use a chaotic maze of fibers to physically capture particles of all sizes through a combination of impaction, interception, and diffusion.

The Three Core Particle Capture Mechanisms

HEPA and ULPA filters do not work like simple sieves. They capture airborne particles through three main mechanisms:

  • Inertial Impaction: Larger particles cannot follow airflow changes and collide with filter fibers, where they are trapped.
  • Interception: Medium-sized particles follow airflow paths and are captured when they contact fiber surfaces.
  • Diffusion: Ultrafine particles move randomly due to Brownian motion, increasing the chance of contact with fibers.

Understanding the Most Penetrating Particle Size (MPPS)

Filter efficiency reaches its lowest point at the Most Penetrating Particle Size (MPPS), typically around 0.1–0.3 µm for HEPA filters. This is why filters are tested at their MPPS to verify worst-case performance.

Particles larger than the MPPS are mainly captured through impaction and interception, while smaller particles are captured through diffusion. ULPA filters achieve higher efficiency by optimizing the filter media structure to improve the capture of ultrafine particles.

Source Certified HEPA & ULPA Filters for Your Application

Need the right filtration solution for your cleanroom or HVAC system? Our engineering team provides OEM HEPA and ULPA filters with customized dimensions, certified performance testing, and reliable factory-direct support.

Get a Custom Filter Quote →

HEPA and ULPA filter solutions

How Are HEPA and ULPA Efficiency Grades Classified?

HEPA and ULPA filter grades are classified by the EN 1822 standard, which evaluates performance based on worst-case efficiency at the Most Penetrating Particle Size (MPPS).

When a filter is labeled as H14 or U15, the classification represents a verified efficiency level defined by IN 1822, rather than a general marketing description. This standard specifies the classification, testing methods, and performance requirements for EPA, HEPA, and ULPA filters.

Filterklasse Filter Type Efficiency at MPPS Typical Applications
H13 HEPA ≥99.95% General cleanrooms, laboratories, healthcare facilities
H14 HEPA ≥99.995% Pharmaceutical production, critical cleanrooms, biosafety laboratories
U15 ZORN ≥99.9995% Semiconductor manufacturing, advanced electronics
U16 ZORN ≥99.99995% Ultra-clean manufacturing processes
U17 ZORN ≥99.999995% Most demanding contamination control applications

Which Filter Designs, Medien, Frames, and Seals Are Available?

HEPA-filter-8

A filter’s performance depends on its physical construction. The design, Medien, rahmen, and seal must all match the specific demands of the application and environment.

Filter Designs and Geometries

Filter geometry affects airflow performance, installation compatibility, and overall system efficiency. Common HEPA and ULPA filter designs include:

  • Box and cylindrical filters: Commonly used in terminal units, laminar flow equipment, and specialized air filtration systems.
  • Pleated filters: Increase media surface area to achieve high filtration efficiency while maintaining reasonable airflow resistance.
  • V-bank filters: Use multiple pleated filter packs arranged in a V-shape to handle high airflow volumes with lower pressure drop, making them suitable for large HVAC and cleanroom systems.

Filter Media Types and Materials

The filter media determines filtration efficiency, Druckabfall, durability, and chemical resistance.

  • Glasfasermedien: A traditional choice for high-efficiency HEPA and ULPA filters, offering excellent particle capture but requiring careful handling due to its fragile structure.
  • Synthetic and PTFE membrane media: Provide improved durability, moisture resistance, and lower pressure drop while maintaining high filtration efficiency, making them suitable for demanding environments.

Frame Constructions and Materials

The filter frame provides structural support and ensures proper installation within the housing. Common frame materials include:

  • Galvanized steel: A cost-effective option for general applications.
  • Aluminium: Lightweight and suitable where weight reduction is important.
  • Edelstahl: Used in pharmaceutical, biotechnology, and other critical environments requiring corrosion resistance and frequent cleaning.

Frame designs may also include protective guards, internal supports, and specialized mounting features to improve durability and installation reliability.

Seal and Gasket Configurations

A reliable sealing system prevents air bypass and ensures the filter achieves its rated performance.

Common sealing options include:

  • Gel seal (knife-edge seal): Provides high leak integrity and is commonly used in critical cleanroom applications requiring strict contamination control.
  • Compression gasket seals: Made from materials such as neoprene, EPDM, or silicone, offering a practical and cost-effective solution for general HEPA installations.

The choice between gel seals and gasket seals depends on application requirements, installation conditions, and whether in-situ leak testing is required.

Where Are HEPA and ULPA Filters Used?

HEPA filters are workhorses in healthcare, industry, and homes. ULPA filters are reserved for ultra-critical applications like advanced semiconductor manufacturing where near-perfect particle removal is mandatory.

The applications for high-efficiency filters are vast, but the choice between HEPA and ULPA is driven entirely by the level of contamination control required. One is a versatile standard, the other is a specialized tool.

Industry HEPA Applications ULPA Applications
Pharmazeutisch GMP cleanrooms, aseptic production areas, laboratories High-critical sterile environments requiring extreme contamination control
Healthcare Operating rooms, isolation rooms, ICUs, medical laboratories Limited use in highly controlled medical and research environments
Halbleiter General clean manufacturing areas and equipment filtration Wafer fabrication, ultra-clean processes, advanced semiconductor production
Elektronik Component assembly areas and general contamination control Advanced microelectronics and precision manufacturing
Industriell Dust collection, hazardous particle filtration, industrial air purification Rarely used except for ultra-sensitive industrial processes

HEPA filters are widely used in healthcare, pharmaceutical manufacturing, electronics, laboratories, and other environments where airborne particle control is required. For applications involving elevated operating temperatures, high temperature HEPA filters are designed with specialized materials and construction to maintain filtration performance under demanding conditions.

How to Select and Specify the Right Filter

Proper filter selection isn’t just about efficiency. It requires matching filter grade and pressure drop to your cleanroom class, HVAC limits, and total lifecycle costs.

Selection Stage Key Specification Actions

Assess Cleanliness Requirements and Process Risk

  • Match cleanroom requirements (such as ISO Class 5–8) with the appropriate filter grade, using HEPA for most applications and ULPA for ultra-clean environments.
  • Identify critical particle sizes and contamination risks affecting product quality.
  • Select filter classes such as H13/H14 HEPA or U15+ ULPA based on industry requirements and standards.

Evaluate HVAC System Compatibility and Constraints

  • Check pressure drop requirements to ensure compatibility with fan capacity and airflow performance.
  • Verify filter dimensions, sealing methods, and housing compatibility before installation.
  • Consider potential system upgrades when switching to higher-efficiency filters such as ULPA.

Define Critical Parameters in the Specification

  • Specify filter efficiency class, testing standard, and required airflow rating.
  • Define construction requirements, including frame material, filter media, and sealing type.
  • Require individual factory test reports and verification procedures for critical applications.

Plan for Lifecycle Cost and Ongoing Validation

  • Evaluate total cost of ownership, including filter cost, energy consumption, and maintenance expenses.
  • Monitor differential pressure and establish replacement criteria based on filter condition.
  • Perform regular integrity testing to maintain filtration performance and compliance.

Testen, Maintenance, and Custom Procurement

A filter’s lifecycle is a closed loop. Test standards dictate procurement, and factory data sets the baseline for maintenance, ensuring long-term system reliability and controlled costs.

Filter Testing and CeCertification and Testing

The performance of HEPA and ULPA filters must be verified through standardized testing rather than relying on manufacturer claims. Filters are tested both before shipment and after installation to confirm filtration efficiency and structural integrity.

Key testing standards include IN 1822, ISO 29463, and IEST Recommended Practices (RPs), which define filter classification and testing procedures.

The main verification methods include:

  • Dichtheitsprüfung: Detects defects such as damaged media, Nadellöcher, or seal failures.
  • Effizienzprüfung: Measures particle removal performance at the filter’s Most Penetrating Particle Size (MPPS).

For critical applications, each filter should be supplied with an individual test certificate showing its measured efficiency, Druckabfall, airflow rating, and leak test results.

Routine Maintenance and Replacement

HEPA and ULPA filter performance gradually decreases as particles accumulate. Regular monitoring and timely replacement help maintain system efficiency and prevent contamination risks.

Maintenance programs typically include:

  • Monitoring differential pressure (ΔP) to track filter loading.
  • Inspecting filter media, frames, and seals for damage.
  • Performing periodic in-situ leak tests to verify installed filter integrity.

Filters should generally be replaced when:

  • They fail an in-situ leak test.
  • Pressure drop exceeds the recommended limit.
  • The filter shows physical or chemical damage.

Custom Procurement Specifications

Selecting high-efficiency filters requires detailed technical specifications rather than a basic purchase order. Procurement documents should clearly define:

  • Filter efficiency class (such as H14 or U15)
  • Required airflow capacity
  • Filter dimensions and housing compatibility
  • Suitable materials for the operating environment

For critical applications, the purchase specification should require individual factory testing and certification before shipment. Additional requirements may include low-outgassing materials for semiconductor applications, chemical-resistant components for pharmaceutical environments, or high-temperature construction for industrial processes.

Häufig gestellte Fragen

What is the difference between HEPA and ULPA filters?

The primary difference is filtration efficiency for very small particles. HEPA filters capture at least 99.97% von 0.3 µm particles. ULPA filters are more efficient, capturing at least 99.999% of even smaller particles around 0.12 µm. This higher performance comes at the cost of increased pressure drop, higher price, and a shorter service life.

What efficiency grades are classified as HEPA and ULPA?

Under the EN 1822/ISO 29463 Standards, filters are classified into different grades. HEPA filters correspond to classes H13 (≥99.95% efficiency) and H14 (≥99.995%). ULPA filters are even more efficient, falling into classes U15 (≥99.9995%), U16, and U17. Lower efficiency filters (E10-E12) are considered EPA filters, not HEPA.

Is ULPA always better than HEPA for a cleanroom?

No. ULPA filters provide higher filtration efficiency but also create greater airflow resistance and higher operating costs. HEPA filters are suitable for most cleanroom applications, while ULPA is mainly used for extremely critical environments such as semiconductor manufacturing.

Which industries typically require H13, H14, or ULPA filters?

H13 and H14 HEPA filters are widely used in healthcare, pharmaceutical manufacturing, and laboratory cleanrooms. H14 is suitable for more critical applications, while ULPA filters are mainly used in industries requiring the highest contamination control, such as semiconductor manufacturing and advanced electronics.

Letzte Gedanken

HEPA and ULPA filters are not interchangeable. HEPA filters meet the needs of most cleanroom and HVAC applications, while ULPA filters are designed for ultra-critical environments where strict particle control is required.

The right choice depends on your cleanliness requirements, airflow system, and operating conditions. Kontaktieren Sie unser Engineering-Team for OEM filter specifications and customized filtration solutions.

Arun Liao

Als Chefingenieur der DTAF, Ich habe 30 Jahrelange Erfahrung in der Klimatisierung und Luftreinigung, Spezialisiert auf die Integration zentraler HVAC-Systeme und hocheffiziente Luftfiltration für gewerbliche und industrielle Anwendungen. Zu meinen Fachgebieten gehört die Raumluftqualität (IAQ), Energieeffizienz, und zuverlässige Systemleistung, mit Erfahrung im Gesundheitswesen, Ausbildung, und Produktionsanlagen. Meine Aufgaben umfassen den gesamten technischen Prozess, Von der Produktentwicklung und Compliance-Validierung bis zur Inbetriebnahme vor Ort und Leistungsüberwachung. Ich glaube, dass gute Technik über Labortestergebnisse hinausgeht. Entscheidend ist die Leistung eines Systems unter realen Betriebsbedingungen – die Aufrechterhaltung einer stabilen Leistung, erfordert nur minimale Wartung, und die spezifischen Anforderungen jedes Standorts langfristig zu erfüllen. Dies ist der technische Standard, den wir bei DTAF anwenden.

Nehmen Sie Kontakt auf

Beliebte Blogs

Anscheinend können wir nicht finden, was Sie suchen.

WhatsApp

Holen Sie sich noch heute Ihre individuelle Filtrationslösung

Kontaktieren Sie unser Engineering-Team für eine kostenlose technische Beratung. Als direkte Fabrik, Wir bieten umfassende Unterstützung von der Rohstoffauswahl bis zur Lieferung des Endprodukts.
Direktpreise ab Werk-1
Direktpreise ab Werk
100K-Klasse Reinraum-1
100Reinraum der K-Klasse
Kundenspezifischer OEM & R&D-1
Kundenspezifischer OEM & R&D
Schnelle globale Lieferung-1
Schnelle weltweite Lieferung

Kontaktieren Sie uns

Kontaktieren Sie uns

Popup-Bild
Ich gehe so bald? Lassen Sie uns Ihre Filtrationskosten optimieren.

Benötigen Sie individuelle Lösungen? Geben Sie unten Ihre Anforderungen ein und unsere Ingenieure unterbreiten Ihnen direkt ab Werk ein Angebot 12 Std..

Laden Sie den neuesten DTAF-Master-E-Katalog herunter

Erhalten Sie vollständigen Zugriff auf technische Spezifikationen, aerodynamische Leistungskurven, und OEM/ODM-Fähigkeiten von Fortune 500 vertrauenswürdiger Filterhersteller.

Direktpreise ab Werk-1
Direktpreise ab Werk
100K-Klasse Reinraum-1
100Reinraum der K-Klasse
Kundenspezifischer OEM & R&D-1
Kundenspezifischer OEM & R&D
Schnelle globale Lieferung-1
Schnelle weltweite Lieferung

Download anfordern

*Wir respektieren Ihre Vertraulichkeit und alle Informationen sind geschützt.